Utilization and Impact of Diabetes Technology among Type 1 Diabetes Patients at a Tertiary Hospital in Thailand

Authors

  • Jirawan Pongrujikorn Chulalongkorn University, Bangkok, Thailand https://orcid.org/0009-0007-1472-7568
  • Jutipond Jitchana King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand
  • Nitchakarn Laichuthai Chulalongkorn University, Bangkok, Thailand

DOI:

https://doi.org/10.15605/jafes.041.02.6355

Keywords:

Diabetes technology, Type 1 Diabetes, Glycemic control

Abstract

Background. While diabetes technologies such as insulin pumps, continuous glucose monitoring (CGM), and automated insulin delivery (AID) systems have demonstrated potential to improve glycemic control and reduce hypoglycemia, their utilization and effectiveness in Thailand remain underdocumented. This study aimed to assess the use and impact of diabetes technologies on glycemic outcomes at King Chulalongkorn Memorial Hospital (KCMH), a tertiary care center in Bangkok, Thailand.

Methodology. A cross-sectional study was conducted among T1D patients receiving care at the endocrinology clinic of KCMH between August 2023 and July 2024. Data were collected at each patient's most recent follow-up visit, and participants were classified into technology users and non-technology users. Data collection focused on demographics, diabetes technology use, and clinical parameters, including HbA1c, hypoglycemia events, and CGM metrics (Time in Range (TIR), Time Above Range (TAR), Time Below Range (TBR)).

Results. A total of 61 patients with T1D were included, of whom 49% were technology users (6% insulin pumps, 57% CGM, 37% AID). Technology users had a significantly higher mean HbA1c (8.1% ± 1.6) than non-technology users (7.2% ± 1.2, p = 0.011). AID users achieved a higher mean TIR (67.6% ± 16%) compared to CGM users (54.0% ± 23.8%), but the difference was not statistically significant. Both AID and CGM users maintained a low incidence of hypoglycemia (<54 mg/dL).

Conclusion. This study found a relatively high rate of diabetes technology adoption at our center compared to other Asian countries, highlighting its potential to reduce the risk of hypoglycemia and improve glycemic stability. However, technology users also had higher HbA1c levels, suggesting that diabetes technology is often prescribed to high-risk patients with poor glycemic control. Future research should focus on longitudinal studies to better understand and address barriers to optimal glycemic outcomes among diabetes technology users.

Downloads

Download data is not yet available.

Author Biographies

Jirawan Pongrujikorn , Chulalongkorn University, Bangkok, Thailand

Division of Endocrinology and Metabolism, Department of Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand

Jutipond Jitchana, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand

Excellence Center in Diabetes, Hormone, and Metabolism, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand

Nitchakarn Laichuthai, Chulalongkorn University, Bangkok, Thailand

Division of Endocrinology and Metabolism, Department of Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand

Excellence Center in Diabetes, Hormone, and Metabolism, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand

References

1. Fullerton B, Jeitler K, Seitz M, Horvath K, Berghold A, Siebenhofer A. Intensive glucose control versus conventional glucose control for type 1 diabetes mellitus. Cochrane Database Syst Rev. 2014;2014(2):CD009122. https://pubmed.ncbi.nlm.nih.gov/24526393 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6486147 https://doi.org/10.1002/14651858.CD009122.pub2

2. Roos T, Hermanns N, Gross C, Kulzer B, Haak T, Ehrmann D. Effect of automated insulin delivery systems on person-reported outcomes in people with diabetes: A systematic review and meta-analysis. EClinicalMedicine. 2024;76:102852. https://pubmed.ncbi.nlm.nih.gov/39364272 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11447321 https://doi.org/10.1016/j.eclinm.2024.102852

3. American Diabetes Association Professional Practice Committee for Diabetes. 7. Diabetes technology: Standards of care in diabetes-2026. Diabetes Care. 2026;49(Suppl 1):S150-65. https://pubmed.ncbi.nlm.nih.gov/41358889 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12690173 https://doi.org/10.2337/dc26-S007

4. Dicembrini I, Cosentino C, Monami M, Mannucci E, Pala L. Effects of real-time continuous glucose monitoring in type 1 diabetes: A meta-analysis of randomized controlled trials. Acta Diabetol. 2021;58(4):401-10. https://pubmed.ncbi.nlm.nih.gov/32789691 https://doi.org/10.1007/s00592-020-01589-3

5. Yeh HC, Brown TT, Maruthur N, et al. Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: A systematic review and meta-analysis. Ann Intern Med. 2012;157(5):336-47. https://pubmed.ncbi.nlm.nih.gov/22777524 https://doi.org/10.7326/0003-4819-157-5-201209040-00508

6. Chen L, Liu X, Lin Q, Dai H, Zhao Y, Shi Z, et al. Status of continuous glucose monitoring use and management in tertiary hospitals of China: A cross-sectional study. BMJ Open. 2023;13(2):e066801.

7. Chandran SR, Ho C, Yeoh E, Gardner D. Type 1 diabetes in Singapore: Self-care challenges, diabetes technology awareness, current use, and satisfaction, an online survey. Indian J Endocrinol Metab. 2024;28(2):167-76. https://pubmed.ncbi.nlm.nih.gov/38911114 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11189278 https://doi.org/10.4103/ijem.ijem_369_22

8. Kim JY, Kim S, Kim JH. Current Status of continuous glucose monitoring use in South Korean type 1 diabetes mellitus population-pronounced age-related disparities: Nationwide Cohort Study. Diabetes Metab J. 2025;49(5):1040-50. https://pubmed.ncbi.nlm.nih.gov/40289448 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12436030 https://doi.org/10.4093/dmj.2024.0804

9. Sato J, Nakajima K, Mita T, et al. Protocol of a prospective observational study on lifestyle and quality of life in adults with type 1 diabetes in Japan. Diabetes Ther. 2024;15(4):883-92. https://pubmed.ncbi.nlm.nih.gov/38363542 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10951137 https://doi.org/10.1007/s13300-024-01539-0

10. Foster NC, Beck RW, Miller KM, et al. State of type 1 diabetes management and outcomes from the T1D exchange in 2016-2018. Diabetes Technol Ther. 2019;21(2):66-72. https://pubmed.ncbi.nlm.nih.gov/30657336 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7061293 https://doi.org/10.1089/dia.2018.0384

11. Beck RW, Riddlesworth T, Ruedy K, et al. Effect of continuous glucose monitoring on glycemic control in adults with type 1 diabetes using insulin injections: The DIAMOND randomized clinical trial. JAMA. 2017;317(4):371-8. https://pubmed.ncbi.nlm.nih.gov/28118453 https://doi.org/10.1001/jama.2016.19975

12. Yordsudueam N, Numsriskulrat N, Lerdrassameethad W, et al. Preliminary clinical outcomes and adoption of continuous glucose monitoring following reimbursement implementation in patients with type 1 diabetes in Thailand. Ann Pediatr Endocrinol Metab. 2026;31(1):66-75. https://pubmed.ncbi.nlm.nih.gov/41354744 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12963732 https://doi.org/10.6065/apem.2550096.048

Downloads

Published

2026-08-07

How to Cite

Pongrujikorn , J., Jitchana, J., & Laichuthai, N. (2026). Utilization and Impact of Diabetes Technology among Type 1 Diabetes Patients at a Tertiary Hospital in Thailand. Journal of the ASEAN Federation of Endocrine Societies, 41(2). https://doi.org/10.15605/jafes.041.02.6355

Issue

Section

Original Articles